Home / Resources / Oil & Gas Engineering Calculators / Required Wall Thickness

Required Wall Thickness

Required Wall Thickness — Calculation Sheet

Required Wall Thickness

Minimum pipe body wall for a target design pressure — API TR 5C3

StandardAPI TR 5C3
MethodBarlow equation (solved for t)
Applies toPipe body, zero axial load
Inputs
Units
Result
t = (P × D) ÷ (factor × 2 × Yp)
Grade
Yp (yield strength)
D (outside diameter)
P (target design pressure)
API wall factor
Result — required wall thickness
Reference & methodology

Standard: API TR 5C3 (formerly API Bulletin 5C3), equivalent methodology to ISO 10400 — this is the same Barlow-equation basis as our Internal Yield (Burst) Pressure calculator, solved for wall thickness instead of pressure.

Formula basis: t = (P × D) ÷ (factor × 2 × Yp). The default wall factor of 0.875 applies API TR 5C3’s standard minimum-wall design case (the −12.5% manufacturing tolerance permitted under API 5CT), so the result is a genuine minimum design wall, not just a nominal-wall screening figure.

Scope and limitations: This sizes the pipe body for internal pressure only — it does not account for collapse (external pressure), combined loading (axial tension/compression, bending), temperature derating, or connection pressure rating. The result is a theoretical minimum; round up to the nearest wall thickness your supplier actually stocks, and re-check that real wall against the burst and collapse calculators.

For preliminary screening only. Not a substitute for a full triaxial (von Mises) load-case analysis or a certified engineering assessment.

Want the worked example and why the wall factor matters here? Read Sizing Pipe Wall Thickness for a Target Design Pressure.

Need help selecting pipe, or a full design case? Talk to an engineer