Required Wall Thickness
Minimum pipe body wall for a target design pressure — API TR 5C3
| Standard | API TR 5C3 |
|---|---|
| Method | Barlow equation (solved for t) |
| Applies to | Pipe body, zero axial load |
| Grade | — |
|---|---|
| Yp (yield strength) | — |
| D (outside diameter) | — |
| P (target design pressure) | — |
| API wall factor | — |
| Result — required wall thickness | — |
Standard: API TR 5C3 (formerly API Bulletin 5C3), equivalent methodology to ISO 10400 — this is the same Barlow-equation basis as our Internal Yield (Burst) Pressure calculator, solved for wall thickness instead of pressure.
Formula basis: t = (P × D) ÷ (factor × 2 × Yp). The default wall factor of 0.875 applies API TR 5C3’s standard minimum-wall design case (the −12.5% manufacturing tolerance permitted under API 5CT), so the result is a genuine minimum design wall, not just a nominal-wall screening figure.
Scope and limitations: This sizes the pipe body for internal pressure only — it does not account for collapse (external pressure), combined loading (axial tension/compression, bending), temperature derating, or connection pressure rating. The result is a theoretical minimum; round up to the nearest wall thickness your supplier actually stocks, and re-check that real wall against the burst and collapse calculators.
For preliminary screening only. Not a substitute for a full triaxial (von Mises) load-case analysis or a certified engineering assessment.